Follow this link to skip to the main content
TURKCE     Referance   About US   Distribution       Apply   Contact  

OUR DIFFERANCE
CONTEMPORARY
COMPREHENSION

SMILING FACE



TEKNOMAR®

is

TEKMER
 &
TEKNOKENT


COMPANY

                   
MODULER CLEAN ROOM BIYOLOGICAL SAFFETY CABIN ETHYLENE OXIDE STERILIZER H2o2 RF PLASMA INDUSTRIAL ETHYLENEOXIDE UV STERILIZER UVION AIR STERILIZER

                     

CHEMOCELL LRCX-UV  
CLASS II B2

BIOLOGICAL   SAFETY   CABINET



GENERAL DEFINITION

CLASS II B2

It is CLASS II B2 type research booth/cabin. Device is being used for drug, chemical, tissue, culture, particle, micro organism, etc. analyses and work on highly contagious viral, genetic, biotech cultures and other organism while protecting technician, environment and specimen with its perpendicular in flow laminar bio safety features in oncology, microbiology, biotechnology, molecular genetic, anthropology, chemotherapy, virology, dna, laboratory, criminology departments,



USING FIELDS

Oncology, Micro-biology, Bio-technology,
Molecular Genetics, Anthropology, Chemotherapy, Virology, DNA, Laboratory, Criminology etc.

FUNCTION FEATURES
This equipment is composed of a ventilation system with laminar flow forming negative and positive pressures, exhaust, dd 7/7 silent nikotra radial fan, EUM pre-filtration absorbing chemicals, HEPA/ULPA filtration system.

UV 254 nm, 30W supporting Air Sterilization System, Electricity, Electronic and Illumination system, all of which are working harmoniously.

The HEPA/ULPA filter in instrument, EU14 (DIN24184, DIN24183-1 , EN 1822 BS 3928) has the quality of monolithic ULPA/HEPA has the absorption capacity of %99.999 for particles bigger than 0,12 / 0,30 microns. Second filter is using for exhaust.

The system works in 3 steps. One of the moods of operation is the economy mood (1/2). Also, there are three different working modes. The equipment adjusts the air flow speed continuously by means of electronic processor control and keeps the medium flow fixed.

The total flowing volume, which is 400- 2040 m³/hour, is adjusted in 4 steps. The laminar flow is min 0.25 m/s -max 0.6 m/s. The negative turbulence pressure is -30 mm/Hg, the station positive pressure is 60mm/Hg.

The front windows have the feature of vertical. The equipment eases the processes of service and loading. It is also ergonomic.

The clean air taken in from the front window at the ratio interval of %10-40 or at the fixed ratio of %30 is filtered first in the pre-eum filter before passing to the HEPAs. The exhausted clean air is sent away from the equipment.

These HEPAs and PREEUM filters are disposable and can be changed without becoming contaminated.

The inner part of the equipment is covered with stainless steel (AISI 316L), outer part is covered either with stainless steel (304) or galvanized Epoxy polyester electro static, mat and powder paint produced from DKP sheet iron resistant to chemicals and ethological agents. The inner working bench is made of stainless steel and it is removable. (It can be mono block or 1 or 4 pieces) The working benches can be smooth or perforated.

The illumination of the Chemocell Lrcx-uv equipment is homogenous, and the fluorescent lamp giving off 1000-2000 lux/m2 light directly without reflection, and it is easy to use. It can be operated manually or automatically.

The vibration is smaller than 0,005 mm rms. The wings of fan pal are balanced.

The sound flowing volume of Chemocell Lrcx-uv is smaller than 50 db (the noise DIN is 12950). It has the noise isolation and isolation against permeating with antistatic iso-polymer materials.

The clean air passed through HEPAs is given in small amounts between the user and the equipment through the front part of the Chemocell Lrcx-uv, thus forming an air safety barrier (the outer space is the negative pressure area.).

The front window and side wall windows are produced from temperature resistant chemical Lexan polycarbonate glass and they are unbreakable.

STANDARDS : ISO 9001-2000, TSEK, CE
(209DIN-BS7526-12950,EN12469-VDI2083)
(PERFORMANCE STANDARDS DIN 12950, DIN 12980, CLASS IIA-IIB1-IIB2-IIB3 BS5726,IEC1010-1,NSF 49, EN12469), filter (DIN24184, 24183-1, EN 1822 BS 3928)

ELECTRONIC CONTROL SYSTEM, PROGRAMME :
(For Standard productions)
In -the electronic control panel, there is digital hepa stoppage indicator, inner-outer heath, air, flowing volume, uv, air flowing speed, flowing volume adjuster, eko mood, alert indicating the type of breakdown, 2 digital counters one of which shows the total processing time of the equipment and the other one shows the working process at that time, a time counter showing the uv and hepa processing time, fan with 1-2-3 operating levels, UV, eco switch (touch keys), front window warning, blower flow fixing.

Chemocell LRCX-UV equipment has the micro processor control and touch key digital control panel.
- The program used in the equipment is written according to the control and safety system. The control screen is LCD and it can show all the parameters. There is also voiced and illuminated warning system

PHYSICAL : (for standard productions)
Inner dimensions of the cabin:
W 100 cm/D 65 cm/H 75 cm,
W 125 cm/D 65 cm/H 75 cm,
W 150 cm/D 65 cm/H 75 cm,
W 180 cm/D 65 cm/H 75 cm,
We are producing this equipment according to the size and features you deserve.

OPTIONAL SPECIFICATIONS - cabinet volumes and according to the size and features you deserve.
- uninterruptible power supply (UPS) (during power outageit is appreciation training of instrument app. 1 (one) hour.
- Touchmatic screen, PLC, modem, RC232, printer, HAP
- Depend on class type, this air is sent out through the spiral pipes connected to the hermetic chimney changing according to the class type.

- Gloves can be assembled optionally (Class IIIA) to the armband holes on the front window 4 - 6 mm of tempered glass can be used optionally.


ACCESSORIES :

Instrument is with conveyor table (stand) foot. The height of the working bench can be adjusted between 75 and 90 cm (adjustable), power socket, gas and vacuum tap.

POWER SUPPLY : 220V or 380 V, 2A, 1ph, 50/60 Hz 450w

WEIGHT : 115 KG


SAFETY

Chemocell lrcx-uv equipment has TSEK, also all electro mechanic parts has ISO, TSE standards and suitable regarding DIN norms. There is control unit against contraband electric current.


        &

WE ARE PRODUCING FOR PROFESSIONALS

 

    Phone: +90 312 385 36 95     Fx: +90 312 385 67 84       06370     Ostim /Ankara/Turkiye          E-Post          ANASAYFA          MAINPAGE
INDUSTRIAL, BIOTECHNOLOGY , ELECTRO-MECHANIC MEDİCAL & LABORATORY EQUIPMENTS ENGINEERING ,R&D PRODUCE